PAL and PAU sections

PAL and PAU sections are ideally suited for the execution of continuous walls that require a limited profile height. The ‘inversed’ interlocks allow the installation of relatively shallow structures.

Their shape has been optimized in order to achieve an excellent section modulus / mass ratio, with section modulus up to 1 100 cm³/m.

Section Dimensions Mass Per metre of wall Coating
area*
Thick-
ness
System
width
Height Single
pile
Wall Section
modulus
Moment
of
inertia
Sectional
area
Single
pile
e A H W I
mm mm mm kg/m kg/m2 cm3 cm4 cm2 m2/m
PAL 30 30 3.0 660 89.0 19.4 29.4 112 500 37.5 0.80
PAL 30 40 4.0 660 90.0 25.8 39.2 147 666 49.9 0.80
PAL 30 50 5.0 660 91.0 32.2 48.8 181 831 62.2 0.80
PAL 31 30 3.0 711 125.0 23.5 33.1 199 1 244 42.2 0.97
PAL 31 40 4.0 711 126.0 31.3 44.0 261 1 655 56.1 0.97
PAL 31 50 5.0 711 127.0 39.0 54.9 322 2 063 70.0 0.97
PAL 32 60 6.0 700 149.0 46.2 66.0 413 3 096 84.1 0.92
PAL 32 70 7.0 700 150.0 53.2 76.0 479 3 604 96.8 0.92
PAL 32 80 8.0 700 151.0 61.6 88.0 545 4 109 112.1 0.92
PAL 32 90 9.0 700 152.0 70.0 100.0 605 4 611 127.4 0.92
PAU 22 40 4.0 921 252 39.0 42.3 404 5 101 53.9 1.22
PAU 22 50 5.0 921 253 48.7 52.8 504 6 363 67.3 1.22
PAU 22 60 6.0 921 253.5 58.3 63.3 600 7 620 80.7 1.22
PAU 24 40 4.0 813 293.0 39.0 48.0 537 7 897 61.1 1.22
PAU 24 50 5.0 813 294.0 48.7 59.9 669 9 858 76.3 1.22
PAU 24 60 6.0 813 295.0 58.3 71.8 801 11 813 91.4 1.22
PAU 27 60 6.0 804 295.0 60.4 75.1 803 12 059 95.7 1.16
PAU 27 70 7.0 804 296.0 70.4 87.5 934 14 030 111.4 1.16
PAU 27 80 8.0 804 297.0 80.3 99.8 1063 15 995 127.1 1.16

*One side, excluding inside of interlocks.